Eaton Magnum Ds Breaker Manual. Magnum DS Arc Quenching Switchgear Eaton Color-Coded Breaker Position Indicators Magnum DS Breakers are 100 per-cent rated, UL listed, and are built and tested in an ISO 9000 certified facility to applicable standards including: ANSI C37.13 NEMA SG3 ANSI C37.16 UL 1066 ANSI C37.17 CSA 22.2 ANSI C37.50 Magnum DS is also suitable for use in: UL 1558 Low Voltage Switchgear Low-voltage switchgear is a metal-enclosed assembly with three-position, draw-out power circuit breakers engineered to monitor and protect low-voltage electrical systems.
Eaton Magnum Ds Manual from wiringguidelingot.z21.web.core.windows.net
Magnum DS low-voltage switchgear offers reliable protection and centralized control of low-voltage power circuits up to 600 volts for a wide range of industries including healthcare, data centers and petrochemical If the Magnum DS breaker solid- to main breakers may assure good another phase, and exceeds the state tripping system including an ground protection
Eaton Magnum Ds Manual
Page 17: High-Resistance Grounding Technical Data Magnum DS Cutler-Hammer Metal-Enclosed Effective: May 1998 Page 17 Low-Voltage Switchgear Application been cleared, the timer will run. circuit breakers user manual (DS, DC, DSX, DSL, and MDE) EATON www .eaton .com Purpose This instructional booklet is expressly intended to cover the installation, operation, and maintenance of Magnum DS® (MDS, MDN, MDE), Magnum DC (DAS, DBS), DSX (MDSX), and Magnum DSL (MDSL) power circuit breakers Color-Coded Breaker Position Indicators Magnum DS Breakers are 100 per-cent rated, UL listed, and are built and tested in an ISO 9000 certified facility to applicable standards including: ANSI C37.13 NEMA SG3 ANSI C37.16 UL 1066 ANSI C37.17 CSA 22.2 ANSI C37.50 Magnum DS is also suitable for use in: UL 1558 Low Voltage Switchgear
Eaton MDS620 3 Pole 2000A 600V Magnum DS DrawOut Circuit Breaker. Magnum DS low-voltage switchgear offers reliable protection and centralized control of low-voltage power circuits up to 600 volts for a wide range of industries including healthcare, data centers and petrochemical Page 17: High-Resistance Grounding Technical Data Magnum DS Cutler-Hammer Metal-Enclosed Effective: May 1998 Page 17 Low-Voltage Switchgear Application been cleared, the timer will run.
Eaton Magnum Ds Breaker Manual. Magnum DS breaker control voltages and currents Control voltage 24 dc 48 dc 125 dc 120 ac 240 ac Close current (SR), ampere 2.70 1.30 0.67 0.59 0.34 Shunt trip current, ampere 2.70 1.30 0.67 0.59 0.34 Spring charge motor, ampere: (9 seconds) N/A 4.00 3.00 3.00 N/A Page 12 Instructions for Magnum DS Metal-Enclosed Instruction Booklet IB01900002E Low-Voltage NEMA 3R Assemblies Effective June 2011 4.5 Traveling Circuit Breaker Lifter The traveling overhead circuit breaker lifter is a standard device installed on these assemblies where an aisle-way is present